        J41B NRS Ammonia Globe Valve

        Product overview

        Product model: J41B
        Nominal diameter: DN15 ~ DN300
        Nominal pressure: PN16 ~ PN25
        Applicable medium: liquid, gas, ammonia, nitrogen, hydrogen
        Applicable temperature: -10℃-150℃
        Body material: cast iron, cast steel
        Drive mode: manual, gear drive, electric, pneumatic, etc
        Design and manufacture: GB12235
        Structure length: GB12221
        Flange size: GB9113 JB79
        Pressure - temperature: GB9131
        Test - inspection: GB/T13927 JB/T9092

        J41B NRS Ammonia Globe Valve product details

        J41B NRS Ammonia Globe Valve structural characteristics and uses
         1, through the flange for the square structure, the stem rod connection. 
         2, the valve body sealing surface using ball convex shape, and the valve to line seal. 
         3, the sealing surface with Babbitt, sealing performance, long service life.


        The J41B NRS Ammonia Globe Valve produced and sold by Baigang Valve Group often uses oxygen, nitrogen, hydrogen, argon and other gases.These gases are generally stored in a special high pressure gas.When in use, the gas pressure is reduced to the range required by the experiment through the ammonia cut-off valve, and then the gas is input into the use system through other control valves.Commonly used pressure reducing valve for ammonia cut-off valve, referred to as ammonia valve.


        J41B NRS Ammonia Globe Valve performance specifications

        Nominal pressure PN (MPA)

        Test pressure PS (MPa)

        Suitable media

        Applicable temperature (℃)

        2.5

        3.8

        Ammonia, 
        ammonia and other 
        NH3

        Babbitt alloy 
         -40 ℃ 
        + 150 ℃

        PTFE 
        -40 ℃ 
        +200 ℃

        4.0

        6.4


        J41B NRS Ammonia Globe Valve main size and weight:

        DN (mm)

        Size (mm)

        L

        D

        D1

        D2

        D4

        b

        f

        f1

        Z-φd

        turn off

        open

        D3

        10

        130

        90

        60

        40

        35

        16

        2

        4

        4-φ14

        165

        185

        110

        15

        130

        95

        65

        45

        40

        16

        2

        4

        4-φ14

        165

        185

        110

        20

        150

        105

        75

        55

        51

        18

        2

        4

        4-φ14

        170

        200

        120

        25

        160

        115

        85

        65

        58

        18

        2

        4

        4-φ14

        197

        210

        120

        32

        180

        135

        100

        78

        66

        20

        2

        4

        4-φ18

        199

        213

        140

        40

        200

        145

        110

        85

        76

        20

        3

        4

        4-φ18

        248

        264

        160

        50

        230

        160

        125

        100

        88

        22

        3

        4

        4-φ18

        265

        295

        180

        65

        290

        180

        145

        120

        110

        24

        3

        4

        8-φ18

        310

        349

        220

        80

        310

        195

        160

        135

        121

        26

        3

        4

        8-φ18

        340

        357

        240

        100

        350

        230

        190

        160

        150

        30

        3

        4.5

        8-φ23

        380

        413

        280

        125

        400

        270

        220

        188

        176

        32

        3

        4.5

        8-φ25

        430

        451

        320

        150

        480

        300

        250

        218

        204

        32

        3

        4.5

        8-φ25

        505

        492

        360

        200

        600

        360

        310

        278

        260

        34

        3

        4.5

        12-φ25

        550

        806

        400

        250

        650

        425

        370

        335

        31

        36

        3

        4.5

        12-φ30

        730

        880

        450

        300

        750

        485

        430

        390

        364

        40

        3

        4.5

        16-φ30

        -

        995

        550


        J41B NRS Ammonia Globe Valve appearance and working principle

         Ammonia valve high pressure chamber and the cylinder connection, low pressure chamber for gas exports, and access to the use of the system. Indication of high pressure gauge is the pressure of gas stored in the cylinder. Low pressure gauge outlet pressure can be controlled by adjusting screw. 
         Open the cylinder main switch when using, then turn the low pressure gauge pressure adjusting screw clockwise to compress the main spring and drive the diaphragm, spring pad and ejector to open the valve. Such imports of high-pressure gas from the high-pressure chamber after throttling decompression into the low-pressure chamber, and through the exit leading to the working system. Turn the adjusting screw to change the opening height of the valve to regulate the passage of high-pressure gas and achieve the desired pressure value. 
         Ammonia cut-off valves are equipped with safety valves. It is to protect the ammonia valve and make it safe to use the device, but also the ammonia valve failure signal device. If due to the valve pad, valve damage or for other reasons, resulting in the pressure on the outlet and rise above a certain allowable value, the safety valve will automatically open the exhaust.

        Fifth, the use of
         (1) according to the different requirements of use, ammonia valve has many specifications. Most of the highest import pressure, the minimum import pressure of not less than 2.5 times the outlet pressure. Export pressure specifications more generally, the maximum outlet pressure.   
         (2) Ammonia valve should be installed to determine whether the connection specifications consistent with the use of the system connector. Ammonia globe valve with hemispherical connection, by tightening the nut so that the two completely match. Therefore, the use of the two hemispherical surfaces should be kept clean to ensure a good airtight effect. Use high-pressure gas to blow off the dust before installation. If necessary, PTFE and other materials can also be used for gaskets. 
         (3) ammonia valve should be prohibited from contact with grease, so as to avoid fire accidents. 
         (4) stop working, the relief valve should be more than air net, and then loosen the adjustment screw to prevent long-term compression of the elastic deformation. 
         (5) Ammonia stop valve should be avoided impact vibration, not with corrosive substances in contact.



        Reminder:

        All text, data and pictures in this article are for reference only.To see more details of the J41B NRS Ammonia Globe Valve performance parameters, structural dimension parameters, pricing, etc., or to request high quality printing samples, please Contact us.