<li id="g6waw"><table id="g6waw"></table></li>
    • <samp id="g6waw"></samp>
      
      
      • Hotline: +86-021-57278880
        Language:   
        Your current location: ProductsMetallurgical ValveElectric Push Rod Blind Valve

        F9T43X Electric Push Rod Blind Valve

        Product overview

        Product model: F9T43X
        Nominal diameter: DN300~2000mm
        Nominal pressure: PN0.05~0.25MPa
        Applicable temperature: ≤300℃
        Applicable medium: gas and poisonous, harmful and flammable gases
        Main materials: carbon steel, stainless steel, silicon rubber
        Drive mode: electric, hydraulic, pneumatic, electro-hydraulic
        Design standard: API 600, API6D, ASME B16.34, GB/T 12234
        Structure length: ASME B16.10, API6D, GB/T 12221
        Connection standard: ASME B16.5, ASME B16.47, GB/T 9113, JB/T 79, HG/T 20592
        Pressure test: API 598, GB/T 13927, JB/T 9092
        Pressure-temperature rating: ASME B16.34, GB/T 12224

        F9T43X Electric Push Rod Blind Valve product details

        F9T43X Electric Push Rod Blind Valve product Overview
        F9T43X Electric Push Rod Blind Valve produced and sold by Baigang valve group, also known as electric push rod fan glasses valve, electric push rod fan flap, mainly by the left valve body, the right valve body, stem, gate , Seals, electric putter and other components, and by the base, the support column to form a rigid structure. Sealing parts with stainless steel and rubber seals, good sealing performance, long service life, set the seal on the gate, easy to replace the seal when the seal, rubber seals set in the gate. Electric push rod blind valve can be a single long-distance control, remote control can also be more than one network, under normal circumstances can also use the valve itself device manual operation.


        F9T43X Electric Push Rod Blind Valve product Features

        1, the valve in the switching process, the door seals no wear and tear, sealing performance and easy to replace the seal.

        2, The transmission uses the principle of the connecting rod mechanism, the structure is simple and suitable for the harsh environment of the work place, the transmission stroke is accurate and the clamping force of the clamping mechanism at the three clamping points is even.

        3, taking into account the structural characteristics of the blind valve, blind valve seal at the weaknesses of two rigid strengthening treatment, the sealing performance more reliable.

        4, electric push rod positioning using a new type of inductive electrical appliances, reducing the sender may produce unnecessary sparks, the use of safer.

        5, due to gas flow, easy to valve stainless steel telescopic bellows erosion phenomena, the valve design in the pipeline chamber bellows diversion sleeve with good wear resistance 16Mn steel while increasing its thickness.

        6, sealing ring material selection of high temperature resistant and gas-resistant fluorine rubber.


        F9T43X Electric Push Rod Blind Valve scope of application

        F9T43X electric push rod blind valve is based on GB6222 "industrial gas safety regulations," the relevant standards while digesting and absorbing advanced technology at home and abroad, based on their own research and development of a new generation of products, mainly used in various industrial and mining enterprises, environmental protection and other industries Gas, air, flue gas and other gas pipeline media, as cut off all kinds of toxic, harmful and reliable device.


        F9T43X Electric Push Rod Blind Valve working principle

        First electric clamping push rod through the motor-driven, the thrust through the crank directly on the active clamping screw stem to rotate and make the three threaded stem through the link mechanism to do synchronous rotation, driven by the respective left and right valve Lever nut so that the left valve body and the valve body in the same time compressing the bellows to the valve plate as the center of the relative movement so that the door gasket completely from the two body seals. Re-start the electric push rod thrust will be the door blind ring and through-ring replacement, electric clamping push rod action again, will clamp the door rubber seal, so as to achieve the valve seal. The door is composed of a blind plate and a through ring. When the tightening mechanism is released, the door can rotate and change positions to realize the valve switch.


        F9T43X Electric Push Rod Blind Valve technical parameters 

        Nominal pressure PN (MPa)

        0.25

        0.15

        0.10

        0.05

        Seal test pressure (MPa)

        0.275

        0.165

        0.11

        0.055

        Strength test pressure (MPa)

        0.375

        0.225

        0.15

        0.075

        Drive source

        Electric device

        Applicable temperature (℃)

        Nitrile rubber

        Silicone Rubber

        fluororubber

        -20-100

        -20-200

        -20-300

        Suitable media

        Gas and other toxic and harmful gases

        Opening and closing time (S)

        ≤ 60

        The main components of the material

        Valve body, the gate for the carbon steel; screw for the alloy steel; nut manganese copper alloy, ductile iron; expansion device for stainless steel


        F9T43X Electric Push Rod Blind Valve size specifications

        DN (mm)

        Overall dimensions (mm)

        D

        D1

        b

        n-φd

        L

        300

        440

        395

        18

        12-φ22

        500

        350

        490

        445

        18

        12-φ22

        600

        400

        540

        495

        24

        16-φ22

        600

        450

        595

        550

        24

        16-φ22

        600

        500

        645

        600

        26

        20-φ22

        600

        600

        755

        705

        26

        20-φ26

        600

        700

        860

        810

        26

        24-φ26

        600

        800

        975

        920

        35

        24-φ30

        800

        900

        1075

        1020

        35

        24-φ30

        800

        1000

        1175

        1120

        35

        28-φ30

        800

        1100

        1275

        1220

        35

        36-φ30

        800

        1200

        1375

        1320

        35

        32-φ30

        800

        1300

        1475

        1420

        35

        36-φ30

        800

        1400

        1575

        1520

        35

        36-φ30

        800

        1500

        1675

        1620

        35

        36-φ30

        850

        1600

        1790

        1730

        35

        40-φ30

        850

        1800

        1990

        1930

        35

        44-φ30

        1100

        2000

        2190

        2130

        35

        46-φ30

        1100



        Reminder: